| 12345678910111213141516171819202122232425262728293031323334353637 |
- {
- "_note": [
- "台架自检模板:**没有相机、没有 .rknn 权重**时也能把整条链路跑起来(合成帧 + mock 检测框 → 判定/投票/证据/Modbus 发布)。",
- "用法:cp configs/bench-synthetic.json configs/site.json && systemctl restart portcv",
- "PLC 侧先对寄存器:Modbus-TCP 0.0.0.0:1502,unit 1,FC4 输入寄存器 0 起读视觉结果、FC3 保持寄存器 0 起写指令;心跳 500 ms。",
- "相机与模型到位后换成 configs/rk3588-rtsp.json(source=rtsp + run.backend=rknn + model.rknn_path)。",
- "注意:mock 后端的判定值是脚本化的,只用于验证链路与寄存器时序,**不能当精度验收**。"
- ],
- "run": {
- "backend": "mock",
- "mode": "composed",
- "max_fps": 10.0,
- "warmup_frames": 2,
- "save_on_change": true,
- "log_json": true
- },
- "source": {
- "type": "synthetic",
- "fps": 10.0,
- "buffer_size": 2,
- "stale_frame_s": 0.6
- },
- "plc": {
- "enabled": true,
- "push": "modbus_server",
- "modbus": {
- "host": "0.0.0.0",
- "port": 1502,
- "unit_id": 1,
- "input_addr": 0,
- "holding_addr": 0,
- "allow_unit_any": true
- },
- "gating": false,
- "heartbeat_ms": 500
- }
- }
|